Electromagnetic Compatibility (EMC) is the ability of electrical or electronic devices to operate in harmony with their environment in their electromagnetic environment. Before each electrical, electronic or electromechanical device is put into user service, EMC tests must be performed to determine that it does not emit unwanted interference signals to its environment, the electrical power lines to which it is fed or the data transmission lines to which it is connected, and that it is not affected by its environment, the electrical power lines to which it is fed or the data transmission lines to which it is connected.

The Electromagnetic Laboratory has two semi-reflection-free rooms of different sizes and two screened rooms where accredited military and commercial EMC experiments can be performed. There is also a fully reflection-free room and an open field test area where the calibrations of the devices used in EMC experiments and electromagnetic pollution measurements are carried out. 

electromagnetic img

Areas of Activity and Services

Accredited military and commercial EMC experiments can be performed in the Electromagnetic Laboratory. At the same time, electric and magnetic field probe calibrations and antenna calibrations are among the fields of activity of the laboratory.

Semi-Reflectionless Room-1

  • Interior dimensions of the room: 18 m (length) x 13 m (width) x 9 m (height)
  • Absorptive material: Ferrite and carbon impregnated hybrid sponges
  • Additional rooms Control and power amplifier rooms
  • Operating frequency range: 9 kHz - 40 GHz
  • Maximum electric field strength: 200 V/m
  • Maximum measurement distance: 10 m
  • Turntable dimensions: Diameter 3 m, maximum weight capacity 5 tons
  • Antenna tower scanning height range: (1 - 4) m
  • NSA (Normalized Field Attenuation) value: Maximum ± 4 dB (30 MHz -1 GHz)
  • SVSWR (Site Voltage Standing Wave Ratio) value: Maximum 6 dB, (1 GHz - 18 GHz)

Semi-Reflectionless Room-2

  • Internal dimensions: 7.72 m (length) x 4.40 m (width) x 2.90 m (height)
  • Absorptive material: Ferrite and carbon impregnated hybrid sponges
  • Operating frequency range: 9 kHz - 40 GHz
  • Maximum electric field strength: 200 V/m

Open Field Experiment Area

  • Earthed surface width: 60 m x 30 m
  • Maximum measurement distance: 30 m
  • Antenna tower scanning height range: (1 - 6) m
  • NSA (Normalized Field Attenuation) value: Maximum ± 1 dB (30 MHz - 1000 MHz)
  • SIL (Site Interference Loss) value: ± 0.6 dB for maximum Horizontal Polarization, ± 1 dB for Vertical Polarization. Meets CISPR 16-1-5 and CISPR 16-1-6 CALTS and REFTS requirements (30 MHz - 1000 MHz)

Full Reflection Room

  • Interior dimensions of the room: 8.89 m (length) x 3.99 m (width) x 3.53 m (height)
  • Absorptive material: Ferrite and carbon impregnated hybrid sponges
  • Operating frequency range: 500 MHz - 40 GHz
  • Maximum electric field strength: 200 V/m

Screened Room-1

  • Internal dimensions: 8.89 m (length) x 3.99 m (width) x 3.53 m (height)
  • Operating frequency range: 10 kHz - 40 GHz
  • Surge tests, explosion tests (EFT/Burst), electrostatic discharge tests (ESD), harmonic currents, flicker, voltage troughs and interruptions tests are carried out in the shielded room.

Screened Room-2

  • Internal dimensions: 5.60 m (length) x 3.70 m (width) x 3.53 m (height)
  • Operating frequency range: 10 kHz - 40 GHz
  • Conduction diffusion and conduction immunity experiments are carried out in the screened room.

Tinnitus Room

  • Internal dimensions: 4.83m m (length) x 3.61 m (width) x 3.05 m (height)
  • Operating frequency range: 200 MHz - 18 GHz
  • It is used in projects and scientific studies.

Services Provided

.cls-1 { fill-rule: evenodd; stroke-width: 0px; }

Calibration / Testing Services

.cls-1 { fill-rule: evenodd; stroke-width: 0px; }

Training Services

.cls-1 { fill-rule: evenodd; stroke-width: 0px; }

Consulting Services

PHYSICS GROUP

Projects and Collaborations

  • EMPIR Project, 22RPT04 "Development of RF and Microwave Metrology Capability II", WP2&WP3-EMC, 2022 - 2025
  • EMPIR Project, 21NMR06 "Metrology for Emerging Electromagnetic Compatibility Standards" (EMC-STD) 2022 - 2025 (Project Coordinator: TÜBİTAK UME)
  • EMPIR Project, 15RPT01 RFMicrowave - "Development of RF and Microwave Metrology Capability", WP3-EMC, 2016 - 2019
  • EMRP Project, IND60 - "Improved EMC Test Methods in Industrial Environments", 2013 - 2016
  • STAGE D-3, "Development Consultancy Service Program for SASO/NMCC", SASO, Saudi Arabia, 2012 - 2014 (Project Coordinator: TÜBİTAK UME)
  • "Establishment of Calibration Laboratory for TEİAŞ", 2013 - 2014
  • EMRP Project, TP4.J07 EMF & SAR, "Traceable measurement of field strength and SAR for the Physical Agents Directive", 2008 - 2011