Semi Anechoic Chamber-1
- Internal dimensions: 18 m (length) x 13 m (width) x 9 m (height)
Absorber material: Ferrite tile and foam absorbers (carbon-based material)
- Additional rooms: Control and power amplifiers rooms
- Operating frequency range: 9 kHz - 40 GHz
- Maximum electric field strength : 200 V / m
- Maximum measuring distance: 10 m
- Turntable dimensions: Diameter 3 m, max. weight capacity of 5 tons
- Scan height range: (1 - 4) m
- NSA (Normalized Site Attenuation) value: Max. ±4 dB (30 MHz – 1000 MHz)
- SVSWR (Site Voltage Standing Wave Ratio) value: Max. 6 dB, (1 GHz – 18 GHz)
Semi Anechoic Chamber-2
- Internal dimensions: 7,72 m (length) x 4,40 m (width) x 2,90 m (height)
- Absorbing material: Ferrite tile and foam absorbers (carbon-based material)
- Operating frequency range: 9 kHz - 40 GHz
- Maximum electric field strength: 200 V / m
Open Area Test Site
- Grounded surface width: 18 m x 22 m
- Maximum measuring distance: 10 m
- Turntable dimensions: Diameter 3 m, max. weight capacity of 3 tons
- Scan height range: (1 - 4) m
- NSA (Normalized Site Attenuation) value: Max. ±1 dB (30 MHz – 1000 MHz)
Full Anechoic Chamber
- Internal dimensions: 8,89 m (length) x 3,99 m (width) x 3,53 m (height)
- Absorber material: Foam absorbers (carbon-based material)
- Operating frequency range: 500 MHz - 40 GHz
- Maximum electric field strength: 200 V / m
Shielded Room-1
- Internal dimensions: 8,89 m (length) x 3,99 m (width) x 3,53 m (height)
- Operating frequency range: 10 kHz - 40 GHz
- Surge immunity, electrical fast transient/burst immunity, electrostatic discharge immunity, voltage dips, short interruptions and voltage variations immunity tests are performed in the shielded room
Shielded Room-2
- Internal dimensions: 5,60 m (length) x 3,70 m (width) x 3,53 m (height)
- Operating frequency range: 10 kHz - 40 GHz
- Conducted immunity and conducted emission tests are performed in the shielded room.
Reverberation Chamber
- Internal dimensions: 4,83 m (length) x 3,61 m (width) x 3,05 m (height)
- Operating frequency range: 200 MHz - 18 GHz
- It is used for scientific researches and project activities.